This guide is for the installer who hangs the letters, and for the sign shop or contractor who sends the crate to site.
Stud mounting means each letter hangs on threaded studs in its back, set into holes drilled in the wall, with nothing showing on the face. The hard part is putting every hole in the right place. Every stud-mounted set we build ships with a full-size 1:1 pattern, so your installer marks the wall through it, drills once and hangs the letters without measuring each one.

Why your installer does not build the pattern
Sign forums still trade tips on putting a pattern together for stud-mounted letters: print the artwork full size, find each stud, mark it, check it against the letters. On our sets that work is done before the crate closes. Stud-mounted letters arrive with threaded studs already set in the back, the stud positions marked on the pattern and the rods cut to length.
Your installer’s work starts at the wall, not at the plotter.

Which letters hang on studs, line by line
Not every letter hangs on studs, and the pattern ships either way.
| Dimensional letters | Channel letters | LED backlit metal | |
|---|---|---|---|
| How it mounts to the wall | Threaded studs set in the back. Some large letters and panels get a folded metal back plate instead | Reverse lit (halo-lit): letters stand off the wall on threaded studs, or sit on a backer panel. On a raceway, letters are fixed on threaded studs and wired. Front lit mounted flush: a back screwed to the wall first | Standoff screws through the face, or a clean face on studs |
| What ships for the install | A printed 1:1 paper pattern, and the rods cut to length | A 1:1 paper pattern | A 1:1 drilling pattern |
| Power | None: no wiring, no power supply | Loose letters: each has its own lead marked + and −. Raceway: one painted raceway carries the letters, the LED wiring and the power supply | A power supply sized to the set |
The dimensional letters page shows both builds, metal and acrylic.
Hanging stud-mounted letters, step by step
- Lay the letters out against the pattern, so each one is matched to its outline before anything goes on the wall.
- Tape the pattern to the wall, level, where the approved mockup places the sign.
- Mark the wall through the pattern at each stud position.
- On reverse lit letters, mark where each lead goes through the wall as well.
- Take the pattern down and drill once at each mark.
- Hang each letter on its studs.
- On lit letters, connect power.
Tape the pattern to the wall, level, where the approved mockup places the sign.
Mark the wall through the pattern at each stud position.Take the pattern down and drill once at each mark.
Hang each letter on its studs.
Where large pieces and lit letters change the job
Not every piece hangs on studs. Some large letters and panels get a folded metal back plate: your crew fixes the plate to the wall with the screws and anchors we pack, then closes the letter or panel over it. Front lit channel letters mounted flush go up the same way. A front lit letter has a back that your crew screws to the wall first; the letter then closes over it and locks with screws on the side.
On LED backlit metal, standoff screws through the face hold the sheet off the wall; that gap is what makes the halo. Floating details are either mounted as separate pieces with their own holes on the pattern, or joined on an acrylic backer so the set hangs as one panel. The LED backlit metal page shows the effects.
Channel letters on a raceway or a backer panel go up as one piece instead of letter by letter. To weigh the three methods, compare raceway, backer and flush mounting.
What to settle before the set is built
The mounting method is chosen with the order, not on site. Send a photo of the wall; our engineering team proposes the mounting method and the pattern, and you can change it before you approve the mockup. You approve a mockup before production: the sign on your site photo or as dimensioned artwork, with overall size and lighting type.
Mark indoor or outdoor on the drawing. Every set ships install-ready, and your installer hangs it. See what install-ready means.

A checklist for install day
- The 1:1 pattern from the crate, with the letters laid out against it
- The approved mockup, for where the sign sits on the wall
- A level and tape for the pattern
- The rods from the crate, for letters on studs
- The screws and anchors we pack, for any piece on a back plate
- Power ready at the wall, for lit letters
Questions about stud-mounted letters
What is stud mounting?
Each letter carries threaded studs on its back. Your installer drills the wall at the stud positions and hangs the letter on its studs, so nothing shows on the face. On our dimensional letters the studs are set in the back before the crate ships, and the pattern marks where they go.
Does every set come with a 1:1 pattern?
Yes. Dimensional letters ship with a printed 1:1 paper pattern, channel letter crates carry one too, and LED backlit metal signs ship with a 1:1 drilling pattern in the box. Your installer marks and drills from it instead of measuring each letter.
Who decides whether the letters go on studs?
Our engineering team proposes it from a photo of the wall, and draws the pattern to match. The method is settled before production: nothing is built until you approve the mockup, and you can change the method up to that point.
Send the request
Add a photo of the wall to the drawing, and mark lit or non-lit for each element. Send us your artwork and target quantity. You get a quote within 24–48 hours and a mockup for approval.